Power switch Expert Power Control 1202-1

Switched and metered Power Control with High-Inrush relays

Remotely switched and metered Power Control with 4 safety sockets for usage in combination with media management systems. The Power Control can be used to switch connected electrical loads on and off and for current measurement. Up to 9 electrical quantities dimensions can be measured on the input side, as well as energy measurement per load output. A combined sensor (temperature and humidity) can be connected to the mini-DIN connector for environment monitoring. Thanks to standardised protocols such as HTTP/HTTPS, Telnet, RADIUS and Modbus TCP, the device can be controlled with a media management system, a server or integrated into a monitoring software. Connecting to Crestron and Extron devices is done quickly thanks to available drivers.

Toolless installation in media or IT racks (19 inches), furniture, pedestals and tables is made possible because the device’s rack ears are already attached. Each output can be switched individually. The outputs can be switched event-based by pre-set sensor thresholds and programmed schedules. The switching state and switch-on delays (0...9999 seconds) are freely adjustable for each Power Port.

The Power Control has an integrated overvoltage protection type 3. This overvoltage protection (OVP) prevents damage to the device and the connected electrical loads (max. L-N, N/L-PE 10 kA). Current peaks are prevented by automatic latency times of one second between the switching of several outputs. In addition, special high-inrush relays prevent the relay contacts from welding during inrush current peaks by withstanding currents of up to 80 A for short periods.

An easily readable LED display shows the relevant status information and the status of the outputs (on/off) directly on the device. This allows a quick overview of total current, IP address and sensor values.

Remote access to the device's web server is possible via an RJ45 network connection and an RS232 interface. In addition, the Power Control Unit can be monitored and controlled while on the move via a mobile device app available free of charge. Furthermore, common security standards are supported (IPv6, SSL, SNMPv3).

Connections

  • 1 power connection (safety socket type F, max. 16 A)
  • 4 load outputs (safety socket type F, max. 16 A)
  • 1 RJ45 network connection (10/100 Mbit/s)
  • 1 Mini-DIN connection for optional sensors


Technical data

  • 19 inch installation: 2 HU
  • Dimensions (LxHxD): 48.4 x 4.6 x 7.4 cm
  • Weight: approx. 1 kg
  • Max. current (total): 16 A
  • Max. current (per port): 16 A
  • Operating temperature: 0-50 °C
  • Storage temperature: -20 - 70 °C
  • Relative humidity: 0 - 95 % (non-condensing)
  • High-Inrush Relay: 80 A up to 20 ms and 20 A up to 4 s
  • Overvoltage protection: L-N 10 kA   
  
Switching functionPer load output
Measuring functionTotal measurement at the input of the device

 

Measured quantities

voltage (V), current (A), frequency (Hz), phase angle (°), active power (W), reactive power (Var), apparent power (VA), power factor (PF), energy (kWh)

Display

4-digit red LED display to show total current, IP address, sensor values and error messages; plain text displays (on/off) for the status of the outputs; three LED indicators for the status of the device, power supply and OVP
Supported protocols                      SNMPv1, v2c, v3; HTTP, HTTPS; SSL, STARTTLS; TLS 1.0, 1.1, 1.2; Syslog; TCP/IP v4, IPv6; DHCP, Telnet, Radius, Modbus TCP

 